BR1500G-GR Features
APC Power-Saving Back-UPS Pro 1500, 230V, Schuko
-
Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
-
Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Automatic Voltage Regulation (AVR)Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Battery replacement without toolsEnables fast battery replacement, lowering Mean Time to Repair (MTTR).
-
Battery-protected and surge-only outletsReserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
-
Boost and Trim Automatic Voltage Regulation (AVR)Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
-
Building Wiring Fault IndicatorThis LED informs users of potentially dangerous wiring problems in the wall circuit.
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Dataline surge protectionProvides protection of connected equipment from power surges on the data lines.
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
-
Extendable Run TimeAdditional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
LCD displayAlpha-Numeric Display which displays system parameters and alarms.
-
LCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.
-
Power-saving outletsAutomatically cuts power to idle equipment to conserve electricity.
-
Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse.
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Serial connectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC’s Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
-
Telephone dataline surge protectionProvides protection of connected equipment from power surges traveling on telephone lines.
-
Transformer-block spaced outletsProtect equipment with input transformer blocks without blocking access to other receptacles.
-
USB connectivityProvides management of the UPS via a USB port (not available on all models).
-
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Pro Features & Benefits
Manageability
-
USB connectionUse your PC to access additional power protection and management features for your UPS via a USB Port.
-
LCD Status DisplayProvides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
Marketing Features
-
Battery-protected and surge-only outletsReserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
-
LCD Status DisplayProvides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
-
Boost Automatic Voltage Regulation (AVR)Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
-
Energy Management FunctionEnergy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Serviceability
-
Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse.
-
Simple battery replacementIncreases UPS availability by allowing quick, easy battery replacement.
Availability
-
Energy Management FunctionEnergy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
-
Customizable voltage-transfer pointsAdjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
-
Customizable voltage sensitivityToggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
-
Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Transformer-block spaced outletsProtect equipment with input transformer blocks without blocking access to other receptacles.
Protection
-
Surge only outletsProtect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
-
Battery and surge protected outletsBack up and protect your hardware and data during power outages, surges and spikes.
-
Dataline surge protectionProvides protection of connected equipment from power surges on the data lines.
Safety
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Output
-
Output power capacity
865 Watts / 1.5 kVA
-
Max Configurable Power (Watts)
865 Watts / 1.5 kVA
-
Nominal Output Voltage
230V
-
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
-
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
-
Topology
Line Interactive
-
Waveform type
Stepped approximation to a sinewave
-
Output Connections(3) Schuko CEE 7 (selector_surgetitle)(3) Schuko CEE 7 (Battery Backup)
-
Transfer Time
10ms typical : 12ms maximum
Input
-
Nominal Input Voltage
230V
-
Input frequency
50/60 Hz +/- 3 Hz (auto sensing)
-
Input Connections
Schuko CEE 7/7P
-
Cord Length
1.83 meters
-
Input voltage range for main operations
176 – 294 V
-
Input voltage adjustable range for mains operation
156 – 300 V
Batteries & Runtime
-
Typical recharge time
8 hour(s)
-
Replacement Battery
-
RBC Quantity
1
-
Battery Volt-Amp-Hour Capacity
187
-
Runtime
-
Efficiency
Communications & Management
-
Interface Port(s)
Optional Simple Signalling RS232 cable , USB
-
Control panel
Multi-function LCD status and control console
Surge Protection and Filtering
-
Surge energy rating
441 Joules
-
Data Line Protection
RJ-11 Modem/Fax/DSL protection (two wire single line), RJ-45 Modem/Fax/DSL protection (four wire dual line)
Physical
-
Maximum Height
301 , 30.1 cm
-
Maximum Width
112 , 11.2 cm
-
Maximum Depth
382 , 38.2 cm
-
Net Weight
13.0 kg
-
Shipping weight
13.8 kg
-
Shipping Height
390 , 39.0 cm
-
Shipping Width
235 , 23.5 cm
-
Shipping Depth
490 , 49.0 cm
-
Units per Pallet
20.0
Environmental
-
Operating Environment
0 – 40 °C
-
Operating Relative Humidity
0 – 95 %
-
Operating Elevation
0-3000 meters
-
Storage Temperature
-15 – 45 °C
-
Storage Relative Humidity
0 – 95 %
-
Storage Elevation
0-15000 meters
-
Audible noise at 1 meter from surface of unit
45.0 dBA
Conformance
-
Approvals
BSI 1363, CE, ENERGY STAR (EU), NEMKO
-
Equipment protection policy
Lifetime : 200000 AUD, Lifetime : 150000 Euros, Lifetime : 75000 GBP
-
Standard warranty
2 years repair or replace, 3 years repair or replace for European Union countries
Sustainable Offer Status
-
RoHS
Compliant
-
REACH
REACH: Contains No SVHCs