One of the most affordable UPS systems in its class, Liebert GXT3 leads the industry in combining small size, high capacity and high reliability features:
- On-line design means zero transfer time from external to internal power. When utility power fails, your critical load remains supported by a seamless flow of power.
- Liebert GXT3 rated output power factor of 0.9 better matches up with switch-mode power supplies used in today’s IT equipment. A higher output power factor allows for a more efficient utilization of the UPS.
- The UPS provides easy serviceability with user replaceable hot-swappable batteries. For maximum control, Liebert GXT3 is custom configurable to your needs using a specially designed Windows software package.
Ideally suited for:
- PCs
- Network workstations
- Servers
- Network closets
- Large network peripherals
- VoIP
Although Liebert GXT3 requires just a slim 2U of rack space, it provides the capabilities of a physically larger system. Get up to 3kVA of capacity and battery backup, in 120V or 230V systems. External battery cabinets may be added for extended run time.
Liebert GXT3 is a true on-line power source, so whatever the quality of power coming in, the pure sinewave output meets the exacting standards of your equipment.
Liebert GXT3 includes:
- Power factor correction
- Internal batteries
- Frequency conversion
- Internal automatic bypass to utility in case of adverse UPS conditions
- Manual bypass capability
- Support for up to four external battery cabinets (rack/tower models)
Liebert GXT3 handles all these potential power problems:
- Power spikes and transients
- EMI/RFI noise
- Voltage sags and brownout conditions
- Harmonics
- Power-factor corrected loads
- Outages
- Frequency variations
| Product Description | Liebert GXT3 1500VA (1350W) 230V Rack/Tower UPS |
| Product Type | Rack/Tower UPS |
| Power Provided | 1500 Watt / 1350 VA |
| Battery | Full Load – 5 minutes Half Load – 16 minutes Recharge Time – 3 Hours to 90% capacity after full discharge with 100% load till UPS auto-shutdown |
| Output AC Parameter | Output Receptacles – 5-15R x 6 Voltage – 110/115/120/127VAC (user-configurable); ±3% Waveform – Sine wave |
| Input Power Cord | 10 ft. attached w/ NEMA 5-15P plug |
| Frequency | 40Hz ~ 70Hz; Auto Sensing |
| Voltage Range | 120VAC nominal; variable based on output load |
| Dimensions (w x d x h) | 430 mm x 467 mm x 85 |
| Weight | 48.5 kg |
| Agency | Safety – UL 1778, cUL Listed RFI/EMI – FCC Part 15, Class A=CISPR22 Class B Surge Immunity – IEC 62040-2 2nd Ed Transportation – ISTA Procedure 1A |