Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Features & Benefits
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Manageability
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Availability
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Marketing Features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Output
Output power capacity
240 Watts / 400 VA
Max Configurable Power (Watts)
240 Watts / 400 VA
Nominal Output Voltage
230V
Output Frequency (sync to mains)
47 - 63 Hz
Output Frequency (not synced)
50Hz +/- 0.1% for 50Hz nominal
Topology
Standby
Waveform type
Stepped approximation to a sinewave
Output Connections
(4) Schuko CEE 7 (selector_surgetitle)
(4) Schuko CEE 7 (Battery Backup)
Transfer Time
6ms typical : 10ms maximum
Input
Nominal Input Voltage
230V
Input frequency
50/60 Hz
Input Connections
Schuko CEE 7/7P
Cord Length
1.83 meters
Input voltage range for main operations
180 - 266 V
Number of Power Cords
1
Maximum Input Current
10.0 A
Batteries & Runtime
Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
The information below is required for social login