Provides notification of changing utility power and UPS power conditions
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Replace Battery LED
An external Replace Battery LED informs the end-user that the battery needs to be replaced.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Back-UPS Features & Benefits
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Manageability
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Availability
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Marketing Features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Output
Output power capacity
390 Watts / 650 VA
Max Configurable Power (Watts)
390 Watts / 650 VA
Nominal Output Voltage
230V
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
50/60 Hz +/-1 Hz
Load Crest Factor
--
Topology
Line Interactive
Waveform type
Stepped approximation to a sinewave
Output Connections
(3) Schuko CEE 7 (Battery Backup)
(1) Schuko CEE 7 (selector_surgetitle)
Transfer Time
6ms typical : 10ms maximum
Input
Nominal Input Voltage
230V
Input frequency
45 - 65 Hz
Input Connections
Schuko CEE 7/7P
Cord Length
1.16 meters
Input voltage range for main operations
140 - 300 V
Maximum Input Current
3.0 A
Batteries & Runtime
Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof